Cleveland-range 22CET6.1 Manuel d'utilisateur Page 2

  • Télécharger
  • Ajouter à mon manuel
  • Imprimer
  • Page
    / 2
  • Table des matières
  • MARQUE LIVRES
  • Noté. / 5. Basé sur avis des utilisateurs
Vue de la page 1
(NOT
T
O SCALE)
SECT
.
B P
AGE
4
0507
Litho in U.S.A.
21.63"
549mm
1.44"
37mm
4.00"
102mm
1.44"
37mm
18.74"
467mm
4.32"
110mm
4.25"
108mm
1.69"
43mm
2.25"
57mm
2.38"
60mm
22.00"
559mm
26.75"
679mm
30.75"
781mm
18.13"
461mm
31.19"
792mm
28.13"
715mm
2
.00"
51mm
217˚
49.32"
1
253mm
D
D
C
C1
C
C2
1.5"
38mm
2.5"
64mm
1.06"
27mm
D
C
RIGHT SIDE VIEWFRONT VIEW
T
OP
VIEW
REAR VIEW
1.5"
3
8mm
3/4” IPS
DRAIN VENT
C
APPED ACCESS
PORT FOR DRAIN
NO
TES
:
Cleveland Range reserves right of design improvement or modification, as warranted.
Many regional, state and local codes exist and it is the responsibility of the owner and installer to comply with the codes.
Cleveland Range equipment is built to comply with applicable standards for manufacturers. Included among those approval agencies are
U.L/NSF#4 and CSA (AGA, CGA).
Each compartment has capacity for: Six, 12˝ x 20˝ x 212˝ deep Cafeteria Pans.
Each compartment has capacity for: Twelve, 12˝ x 20˝ x 1˝ deep Cafeteria Pans.
Each compartment has capacity for: Four, 12˝ x 20˝ x 4˝ deep Cafeteria Pans.
COLD WATER
C-1: Feed water for reservoir, 35 Psi Minimum, 60 Psi Maximum.
C-2: Drain condenser water, 35 Psi Minimum, 60 Psi Maximum.
Two 3/4" NH-F (Garden Thread) connections. Use NSF approved hose.
DRAIN CONNECTION
1 1/4 " NPT-M
Do not connect other units to this drain.
Drain line must be vented. Vented drain connection included.
Do not connect drain to PVC pipe.
OPERATING CLEARANCES
3" Left, 3" Right and 4" Rear.
SERVICE CLEARANCES
12" on control side. Contact factory for variances to clearances.
CONTROLS
SureCook 60-minute electro mechanical timer with load compensating feature.
Three function control switch for Timed Cooking and Continuous Steaming.
APPROVALS
UL and
C
UL listed, classified to NSF#4 and Energy Star
H
D
C
C1 C2
ELECTRICAL
W
A
TTS
VOL
TS
PHASE WIRES
CYCLE
AMPS
SUPPLY CONNECTION
HERTZ WIRE SIZE (COPPER)*
Standard Wattage
Thr
ee Phase - 9 kW Standar
d
13500 208 3 3 60 37.5 6
11300 220 3 3 60 29.7 8
13500
240 3 3 60 32.5 8
11300 440 3 3 60 14.9 12
13500
480
3 3 60 16.2 10
Optional Low Wattage
Three Phase - 6 kW option
9400
208
3
3
60 26.1 8
5440 220 3 3 60 20.9 10
9400 240 3 3 60 22.6 10
5440 440 3 3 60 10.4 14
9400 480 3 3 60 11.4 14
* For supply connection use only copper wire suitable for at least 75˚C. (167˚F).
W
A
TTS
VOL
TS
PHASE WIRES
CYCLE
AMPS
SUPPLY CONNECTION
HERTZ WIRE SIZE (COPPER)*
Standard Wattage
Single Phase - 9 kW Standar
d
13500 208 1 2 60 64.9 4
11300 220 1 2 60 51.4 6
13500
240 1 2 60 56.3 4
11300 440 1 2 60 25.8 8
13500
480
1 2 60 28.1 8
Optional Low Wattage
Single Phase - 6 kW option
9400
208
1
2
60 45.2 6
5440 220 1 2 60 36.1 8
9400 240 1 2 60 39.2 8
5440 440 1 2 60 18.0 10
9400 480 1 2 60 19.6 10