Service & Parts ManualConvotherm Combination Oven-Steamer MODELS: Electric 20.20OEB-20.20OES-20.2007061333 East 179th St., Cleveland, Ohio, U.S.A
NOTES:Cleveland Range reserves right of design improvement or modification, as warranted.Many regional, state and local codes exist and it is the resp
1333 East 179th St., Cleveland, Ohio, U.S.A. 44110Ph: 1-216-481-4900 Fx: 1-216-481-3782 Web Site: www.clevelandrange.comCleveland Range, LLCS
NOTES:Cleveland Range reserves right of design improvement or modification, as warranted.Many regional, state and local codes exist and it is the resp
Figure 4-1a Control Panel CONTROL PANEL BASIC OPERATION A. QUICK START GUIDE ALWAYS PRE-HEAT THE OVEN CHAMBER! 1. Switch on with key (1). 2. Se
Figure 4-1b Control Panel B. CONTROL PANEL DETAIL VIEW Note: Item numbers correspond to numbers on the control panels in Figure 4-1b 1. ON/OFF When
Function Indicators • Light up when function or activity is engaged: 10. Reduced Power 11. Burner or Electric Heating ON 12. Reduced Fan Speed 13. Co
CAUTION Clean the oven chamber at least once per day or more frequently as needed Failure to clean the Combi properly and regularly can cause equipmen
CAUTION Do NOT use U-Shaped racks that are bent or otherwise damaged in any way. Pans and accessories placed in damaged racks can tip and spill, causi
Drain Cover and Drain e. Clean the Bypass Measuring Aperture. (Opening in the oven chamber on the left-hand side, slightly below the door latch. See
B. Semi-Automatic Cleaning of the Oven Chamber NOTE: Do NOT press the Start/Stop key while using the Semi-automatic Cleaning process. This stops the
Table of ContentsInstallation For the Installer . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1Warranty .
a. The third step is Steam mode at 86°F for 1 minute. No action is needed. b. The fourth step is Steam at 212°F for 10 minutes, followed by a Signal
CAUTION Always make sure the cleaning agent containers are correctly connected to the Combi CONVOClean => RED CONVOCare => BLUE or WHITE C. CON
3 “Strong Soiling” 2 hours. 4 ‘Strong Soiling – Shining+” 2 hours and 45 minutes. 8. Press the Smart Key. 9. “Food inside oven?” appears in t
CAUTION Use ONLY the DISSOLVE® Descaler method using Part No. 106174 to descale the Combi. Read, understand, and follow both the descaling procedure i
WARNING This procedure is slightly different depending on the model being descaled. This entire procedure should be read and fully understand as it a
• While adding liquid to the steam generator through the descaler inlets, pour slowly to avoid overflow. • Wipe up any spills at once to avoid etching
C3216313 B0706CLEVELAND RANGE, LLC1333 East 179th St., Cleveland, Ohio 44110-2574THIS DESIGN DESCRIBES A PROPRIETARY ITEM AND IS THE PROPERTY OF CLEVE
C3216313 B0706IITTEEMM QQTTYY PPAARRTT NN00.. DDEESSCCRRIIPPTTIIOONN1 1 C2114828 ASSEMBLY/WELDMENT, TOP, INTERMEDIATE, 12.20/20.20 2 1 C2115487 ASS
C3216313 B0706CLEVELAND RANGE, LLC1333 East 179th St., Cleveland, Ohio 44110-2574THIS DESIGN DESCRIBES A PROPRIETARY ITEM AND IS THE PROPERTY OF CLEVE
C3216313 B0706IITTEEMM QQTTYY PPAARRTT NN00.. DDEESSCCRRIIPPTTIIOONN1 1 C2114828 ASSEMBLY/WELDMENT, TOP, INTERMEDIATE, 12.20/20.202 1 C2115487 ASSE
FOR THE INSTALLER ALL SERVICE MUST BE PERFORMED BY A QUALIFIED CLEVELAND RANGE AUTHORIZED TECHNICIAN. This Installation Manual
3005021 B0706COMPONENT PANEL ASSEMBLY, 480VOEB 20.20 MODELS CLEVELAND RANGE, LLC1333 East 179th St., Cleveland, Ohio 44110-2574THIS DESIGN DESCRIBES A
3005021 B0706COMPONENT PANEL ASSEMBLY, 480VOEB 20.20 MODELS IITTEEMM QQTTYY PPAARRTT NN00.. DDEESSCCRRIIPPTTIIOONN1 1 C5115405 PLATE, ELECTRICAL
IITTEEMM QQTTYY PPAARRTT NN00.. DDEESSCCRRIIPPTTIIOONN1 1 C2114297 WELDMENT, CONTROL PANEL2 1 C5019101 CONTROLLER, 5010 OPERATING MODULE3 1 C
IITTEEMM QQTTYY PPAARRTT NN00.. DDEESSCCRRIIPPTTIIOONN1 4 100413 FOOT ASS'Y, ADJUSTABLE (FOR 1.250 SQ. TUBING), ANCHORABLE TIEDOWN2 1 C21154
IITTEEMM QQTTYY PPAARRTT NN00.. DDEESSCCRRIIPPTTIIOONN1 2 300407 FILTER, ELECTRICAL2 4 300509 TERMINAL, 18-22 AWG PIGGY BACK3 9 111647 CLAMP,
IITTEEMM QQTTYY PPAARRTT NN00.. DDEESSCCRRIIPPTTIIOONN1 1 300453 VALVE ASSEMBLY, 3WAY 240VAC2 3 300407 FILTER, ELECTRICAL3 6 300509 TERMINAL
IITTEEMM QQTTYY PPAARRTT NN00.. DDEESSCCRRIIPPTTIIOONN1 1 C2314219 WELDMENT, STEAM GEN, ELEC, 20.202 2 C6015022 FLAT GASKET 60 x 48.5 x 2 FOR
IITTEEMM QQTTYY PPAARRTT NN00.. DDEESSCCRRIIPPTTIIOONN1 1 300507 DRAIN PUMP, 230 V2 1 111676 BRACKET,PUMP MTG,OEB 20.203 4 111633 SCREW, HEX
IITTEEMM QQTTYY PPAARRTT NN00.. DDEESSCCRRIIPPTTIIOONN1 1 C2514363 ASSEMBLY, OUTER DOOR, 20.202 1 C2514394 ASSEMBLY, INNER DOOR, 20.203 1 C
IITTEEMM QQTTYY PPAARRTT NN00.. DDEESSCCRRIIPPTTIIOONN1 1 C2614806 CARRIAGE PLATE, WELDED, 6.20C2614807 CARRIAGE PLATE, WELDED, 10.10 & 10.
Cleveland STATEMENT OF POLICIES L I M I T E D W A R R A N T Y CLEVELAND RANGE products are warranted to the original purchaser to be free from defec
AEDDEBCINSTALLEDORIENTATIONSECTION E-EDETAIL CDETAIL B DETAIL ASECTION D-D4119 20 81472113 214216182011 211017172214 213 961558 14418C2614801 B, C2614
54321C3216313 B0706EXTERIOR SHEETINGALL 20.20 MODELSIITTEEMM QQTTYY PPAARRTT NN00.. DDEESSCCRRIIPPTTIIOONN1 1 C2514356 DOOR, 20.20, COMPLETE2 1 C21
CLEVELAND RANGE OEB 20.20 SEQUENCE OF OPERATIONS When using these instructions refer to the OEB 20.20 wiring schematic. 1 When incoming power (
• If the ground is not found 220 VAC is sent from terminal 7 on connector X12 on the Control Board (A10) to the fill solenoid (Y3) • The fill soleno
• For the first 2 minutes 220 VAC is sent from terminal 4 on connector X11 through the normally closed auxiliary contacts of contactor K5 to the K50
5 With the combi in the Hot Air mode with time on the timer, the door closed and the start switch is depressed a The front display will include a li
◊ The normally closed auxiliary contact of K4 opens preventing the Steam Contactor K1 from energizing • 220 VAC is sent from terminal 7 of connecto
• For the first 2 minutes 220 VAC is sent from terminal 4 on connector X11 through the normally closed auxiliary contacts of contactor K5 to the K50
◊ The contactor K44 closes and the third leg of 220 VAC is sent to the 18 KW element (E4) ◊ If the reduced power option is chosen then the K44 Conta
• For 15 seconds the motor is de-energized and allowed to coast. • For the next 2 minutes 220 VAC is sent from terminal 3 on connector X11 through t
GENERAL INFORMATION ABOUT COMBIS A. PRODUCT INFORMATION Cleveland Range, LLC assigns two product identification numbers to each Combi: a model nu
e When the condensate box is heated to 140 degrees F at the B3probe, 220 VAC is sent from terminal 5 of connector X12 to the condenser valve (Y1) unt
CLEVELAND RANGE, LLC1333 East 179th St., Cleveland, Ohio 44110-2574VOLTAGE: WATTAGE: CURRENT: DATESHEET OF REVDRAWN BYDRAWING NO.THIS DESIGN DE
BK 2/0BK 2/0BK 2/0-K0GND-X10L1 L2 L3/3.E8126-K113524635E3BK 10-E112.54KW31.5A(@230 VAC)10.111.112.1-X10GND10.211.212.2-K2135246E4-E212.54KW31.5A(@230
-K41135246E2 BK 8 -E41 15.75KW39.6A(@230 VAC)10.411.412.4-X10GND35246GND135246GND135246GND-X12112345621 22C2C2C2HOT AIR(TOP OUTER)/5.A1/5.A1/5.
2112345621 22/5.C2/5.C2FAN SLOW13 14/5.C2/6.D5-A10:X11:6/2.E6-K3:A2RD 18 22 21-K55.1E5 22 21-K56E6D512345621 22/5.C3/5.C3FAN FAST13 14/5.C3C7123456
13-Q57.2 14C6-Q57.1 14RD 18C2 13RD 18-X13:4/E51.6-2.5A(1.6A)42W / RD42U / WHTW/GYTW/GY-M1GND1V / BU1W / BN1U / BK2V / YEFANM 3~-X13.1-X13.221123939C8
CABLE CONNECTION SM ON BM CONTROL 50010JUMPERFBS2-6-X10:20/2.E1L2-X1021-X10:DC8X39: 1OPERATION MODULEBM 5010MODULE(OPTION)-A12PICTO-A11-A10X18:1GEN FI
-K02-K1-K264153-K41-K42-K61-K62-K3-E112.54KW31.5A(@230VAC)-E2-E3 -E4115.75KW39.6 (@230VAC) -E42 -E61 -E622W / RD2U / WH-M11V / BU1W / BN1U / BK2
CONTROL BOARDSM 5010L1- 2O8/240-INPUTMOTOR OVER TEMPDEHUMIDICATION/VALVECONDENSOR/VALVEGEN FILL/VALVEMOTOR OVER TEMPMOTOR / RIGHTMOTOR / LEFTMOTOR / F
CLEVELAND RANGE OES 20.20 SEQUENCE OF OPERATIONS When using these instructions refer to the OES 20.20 wiring schematic. 1 When incoming power (220
INSTALLATION INSTRUCTIONS A. GENERAL This equipment should be installed only by qualified, professional plumbers, pipe fitters, and electricians.
◊ The normally closed auxiliary contacts of K55.1, K55.2 and K56 open preventing the K57 contactor from energizing. • If the combi fan is in the red
e When the condensate box is heated to 140 degrees F at the B3 probe, 220 VAC is sent from terminal 5 of connector X12 to the condenser valve (Y1) un
• For the next 2 minutes 220 VAC is sent from terminal 3 on connector X11 through the normally closed auxiliary contacts of contactor K50 to the K5 c
K57 to the coils of contactor K56 and contactors K55.1 for the upper motor and K55.2 for the lower motor ◊ The K56 contactor closes sending 220 VAC t
◊ The Contactors K42 and K62 close and 220 VAC is sent to the inner elements (E42 and E62) ◊ If the reduced power option is chosen then Contactors
◊ The K57 contactor closes (a) 220 VAC is sent through the Q57.1 thermal overload to the motor and the upper motor turns at a reduced speed. (b) 220
f When the timer counts to 0 or the core temp probe (B10) reaches the set amount the cycle ends and the steam generator reverts to the standby temper
-B10-B7.1-B6-B5-B3-A13-A11-A10LABELC5013001C5001041C5016006C5016007CORE TEMP. PROBE (KTM CTC)OVEN HI-TEMP THERMOSTATOVEN PROBEBYPASS PROBE6.A43.D86.A4
BK 2/0BK 2/0BK 2/0-K0GND-X10L1 L2 L3/3.E812635BU 18/6.F1-X10.21/4.C1-G1:N/4.E1-K5:A2/3.E1-K41:A210.311.312.3-X10/3.A1/3.A1/3.A1FBS 2-I6FBS 2-16FBS 2-1
-K41135246E2 BK 8 -E41 15.75KW39.6A(@230 VAC)10.411.412.4-X10GND35246GND135246GND135246GND-X12112345621 22C2C2C2HOT AIR(TOP OUTER)/5.A1/5.A1/5.
B. INSTALLATION OF THE COMBI – General Instructions General Instructions: 1. Select the Combi’s operating location. 2. Complete the water, dra
2112345621 22/5.C2/5.C2FAN SLOW13 14/5.C2/6.D5-A10:X11:6/2.E6-K3:A2RD 18 22 21-K55.1E5 22 21-K56E6D512345621 22/5.C3/5.C3FAN FAST13 14/5.C3C7123456
13-Q57.2 14C6-Q57.1 14RD 18C2 13RD 18-X13:4/E51.6-2.5A(1.6A)42W / RD42U / WHTW/GYTW/GY-M1GND1V / BU1W / BN1U / BK2V / YEFANM 3~-X13.1-X13.221123939C8
CABLE CONNECTION SM ON BM CONTROL 50010JUMPERFBS2-6-X10:20/2.E1L2-X1021-X10:DC8X39: 1OPERATION MODULEBM 5010MODULE(OPTION)-A12PICTO-A11-A10X18:1WATER
-K0264153-K41-K42-K61-K62 -E4115.75KW39.6 (@230VAC) -E42 -E61 -E622W / RD2U / WH-M11V / BU1W / BN1U / BK2V / YEFAN22 1422 141212FAN FAST-K55.142
CONTROL BOARDSM 5010L1- 2O8/240-INPUTMOTOR OVER TEMPDEHUMIDICATION/VALVECONDENSOR/VALVEMOTOR OVER TEMPMOTOR / RIGHTMOTOR / LEFTMOTOR / FASTMOTOR / SLO
C. SPECIAL INSTRUCTIONS FOR CASTER EQUIPPED COMBI STANDS AND COMBIS 1. Read all instructions before beginning installation. 2. Level the floor
1333 East 179th St., Cleveland, Ohio, U.S.A. 44110Ph: 1-216-481-4900 Fx: 1-216-481-3782 Web Site: www.clevelandrange.comCleveland Range, LLCS