Cleveland-range ELECTRIC 20.20 OES-20.20 Manuel d'utilisateur

Naviguer en ligne ou télécharger Manuel d'utilisateur pour Four Cleveland-range ELECTRIC 20.20 OES-20.20. Cleveland Range ELECTRIC 20.20 OES-20.20 User Manual Manuel d'utilisatio

  • Télécharger
  • Ajouter à mon manuel
  • Imprimer

Résumé du contenu

Page 1 - Service & Parts Manual

Service & Parts ManualConvotherm Combination Oven-Steamer MODELS: Electric 20.20OEB-20.20OES-20.2007061333 East 179th St., Cleveland, Ohio, U.S.A

Page 2 - Table of Contents

NOTES:Cleveland Range reserves right of design improvement or modification, as warranted.Many regional, state and local codes exist and it is the resp

Page 3 - FOR THE INSTALLER

1333 East 179th St., Cleveland, Ohio, U.S.A. 44110Ph: 1-216-481-4900 Fx: 1-216-481-3782 Web Site: www.clevelandrange.comCleveland Range, LLCS

Page 4

NOTES:Cleveland Range reserves right of design improvement or modification, as warranted.Many regional, state and local codes exist and it is the resp

Page 5

Figure 4-1a Control Panel CONTROL PANEL BASIC OPERATION A. QUICK START GUIDE ALWAYS PRE-HEAT THE OVEN CHAMBER! 1. Switch on with key (1). 2. Se

Page 6 - INSTALLATION INSTRUCTIONS

Figure 4-1b Control Panel B. CONTROL PANEL DETAIL VIEW Note: Item numbers correspond to numbers on the control panels in Figure 4-1b 1. ON/OFF When

Page 7

Function Indicators • Light up when function or activity is engaged: 10. Reduced Power 11. Burner or Electric Heating ON 12. Reduced Fan Speed 13. Co

Page 8

CAUTION Clean the oven chamber at least once per day or more frequently as needed Failure to clean the Combi properly and regularly can cause equipmen

Page 9

CAUTION Do NOT use U-Shaped racks that are bent or otherwise damaged in any way. Pans and accessories placed in damaged racks can tip and spill, causi

Page 10 - OGS 20.10

Drain Cover and Drain e. Clean the Bypass Measuring Aperture. (Opening in the oven chamber on the left-hand side, slightly below the door latch. See

Page 11 - Cleveland Range

B. Semi-Automatic Cleaning of the Oven Chamber NOTE: Do NOT press the Start/Stop key while using the Semi-automatic Cleaning process. This stops the

Page 12 - OGB 20.20

Table of ContentsInstallation For the Installer . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1Warranty .

Page 13 - BASIC OPERATION

a. The third step is Steam mode at 86°F for 1 minute. No action is needed. b. The fourth step is Steam at 212°F for 10 minutes, followed by a Signal

Page 14 - Programming / Help

CAUTION Always make sure the cleaning agent containers are correctly connected to the Combi CONVOClean => RED CONVOCare => BLUE or WHITE C. CON

Page 15 - Settings

3 “Strong Soiling” 2 hours. 4 ‘Strong Soiling – Shining+” 2 hours and 45 minutes. 8. Press the Smart Key. 9. “Food inside oven?” appears in t

Page 16 - CAUTION

CAUTION Use ONLY the DISSOLVE® Descaler method using Part No. 106174 to descale the Combi. Read, understand, and follow both the descaling procedure i

Page 17

WARNING This procedure is slightly different depending on the model being descaled. This entire procedure should be read and fully understand as it a

Page 18

• While adding liquid to the steam generator through the descaler inlets, pour slowly to avoid overflow. • Wipe up any spills at once to avoid etching

Page 19

C3216313 B0706CLEVELAND RANGE, LLC1333 East 179th St., Cleveland, Ohio 44110-2574THIS DESIGN DESCRIBES A PROPRIETARY ITEM AND IS THE PROPERTY OF CLEVE

Page 20

C3216313 B0706IITTEEMM QQTTYY PPAARRTT NN00.. DDEESSCCRRIIPPTTIIOONN1 1 C2114828 ASSEMBLY/WELDMENT, TOP, INTERMEDIATE, 12.20/20.20 2 1 C2115487 ASS

Page 21

C3216313 B0706CLEVELAND RANGE, LLC1333 East 179th St., Cleveland, Ohio 44110-2574THIS DESIGN DESCRIBES A PROPRIETARY ITEM AND IS THE PROPERTY OF CLEVE

Page 22

C3216313 B0706IITTEEMM QQTTYY PPAARRTT NN00.. DDEESSCCRRIIPPTTIIOONN1 1 C2114828 ASSEMBLY/WELDMENT, TOP, INTERMEDIATE, 12.20/20.202 1 C2115487 ASSE

Page 23 - DESCALE STEAM GENERATOR

FOR THE INSTALLER ALL SERVICE MUST BE PERFORMED BY A QUALIFIED CLEVELAND RANGE AUTHORIZED TECHNICIAN. This Installation Manual

Page 24

3005021 B0706COMPONENT PANEL ASSEMBLY, 480VOEB 20.20 MODELS CLEVELAND RANGE, LLC1333 East 179th St., Cleveland, Ohio 44110-2574THIS DESIGN DESCRIBES A

Page 25

3005021 B0706COMPONENT PANEL ASSEMBLY, 480VOEB 20.20 MODELS IITTEEMM QQTTYY PPAARRTT NN00.. DDEESSCCRRIIPPTTIIOONN1 1 C5115405 PLATE, ELECTRICAL

Page 26 - C2002042

IITTEEMM QQTTYY PPAARRTT NN00.. DDEESSCCRRIIPPTTIIOONN1 1 C2114297 WELDMENT, CONTROL PANEL2 1 C5019101 CONTROLLER, 5010 OPERATING MODULE3 1 C

Page 27 - C3216313 B

IITTEEMM QQTTYY PPAARRTT NN00.. DDEESSCCRRIIPPTTIIOONN1 4 100413 FOOT ASS'Y, ADJUSTABLE (FOR 1.250 SQ. TUBING), ANCHORABLE TIEDOWN2 1 C21154

Page 28

IITTEEMM QQTTYY PPAARRTT NN00.. DDEESSCCRRIIPPTTIIOONN1 2 300407 FILTER, ELECTRICAL2 4 300509 TERMINAL, 18-22 AWG PIGGY BACK3 9 111647 CLAMP,

Page 29 - 2020 ELECTRIC INJ W CLEANING

IITTEEMM QQTTYY PPAARRTT NN00.. DDEESSCCRRIIPPTTIIOONN1 1 300453 VALVE ASSEMBLY, 3WAY 240VAC2 3 300407 FILTER, ELECTRICAL3 6 300509 TERMINAL

Page 30 - OEB 20.20 MODELS

IITTEEMM QQTTYY PPAARRTT NN00.. DDEESSCCRRIIPPTTIIOONN1 1 C2314219 WELDMENT, STEAM GEN, ELEC, 20.202 2 C6015022 FLAT GASKET 60 x 48.5 x 2 FOR

Page 31

IITTEEMM QQTTYY PPAARRTT NN00.. DDEESSCCRRIIPPTTIIOONN1 1 300507 DRAIN PUMP, 230 V2 1 111676 BRACKET,PUMP MTG,OEB 20.203 4 111633 SCREW, HEX

Page 32 - ALL MODELS

IITTEEMM QQTTYY PPAARRTT NN00.. DDEESSCCRRIIPPTTIIOONN1 1 C2514363 ASSEMBLY, OUTER DOOR, 20.202 1 C2514394 ASSEMBLY, INNER DOOR, 20.203 1 C

Page 33 - OGB 20.20 MODELS

IITTEEMM QQTTYY PPAARRTT NN00.. DDEESSCCRRIIPPTTIIOONN1 1 C2614806 CARRIAGE PLATE, WELDED, 6.20C2614807 CARRIAGE PLATE, WELDED, 10.10 & 10.

Page 34 - OES 20.20 MODELS

Cleveland STATEMENT OF POLICIES L I M I T E D W A R R A N T Y CLEVELAND RANGE products are warranted to the original purchaser to be free from defec

Page 35

AEDDEBCINSTALLEDORIENTATIONSECTION E-EDETAIL CDETAIL B DETAIL ASECTION D-D4119 20 81472113 214216182011 211017172214 213 961558 14418C2614801 B, C2614

Page 36 - OEB-20.20 MODELS

54321C3216313 B0706EXTERIOR SHEETINGALL 20.20 MODELSIITTEEMM QQTTYY PPAARRTT NN00.. DDEESSCCRRIIPPTTIIOONN1 1 C2514356 DOOR, 20.20, COMPLETE2 1 C21

Page 37 - PUMP, STEAM GENERATOR

CLEVELAND RANGE OEB 20.20 SEQUENCE OF OPERATIONS When using these instructions refer to the OEB 20.20 wiring schematic. 1 When incoming power (

Page 38 - 20.20 MODELS

• If the ground is not found 220 VAC is sent from terminal 7 on connector X12 on the Control Board (A10) to the fill solenoid (Y3) • The fill soleno

Page 39 - SLIDING PLATE, COMPLETE

• For the first 2 minutes 220 VAC is sent from terminal 4 on connector X11 through the normally closed auxiliary contacts of contactor K5 to the K50

Page 40 - Page 2 of 2

5 With the combi in the Hot Air mode with time on the timer, the door closed and the start switch is depressed a The front display will include a li

Page 41 - ALL 20.20 MODELS

◊ The normally closed auxiliary contact of K4 opens preventing the Steam Contactor K1 from energizing • 220 VAC is sent from terminal 7 of connecto

Page 42 - SEQUENCE OF OPERATIONS

• For the first 2 minutes 220 VAC is sent from terminal 4 on connector X11 through the normally closed auxiliary contacts of contactor K5 to the K50

Page 43

◊ The contactor K44 closes and the third leg of 220 VAC is sent to the 18 KW element (E4) ◊ If the reduced power option is chosen then the K44 Conta

Page 44

• For 15 seconds the motor is de-energized and allowed to coast. • For the next 2 minutes 220 VAC is sent from terminal 3 on connector X11 through t

Page 45

GENERAL INFORMATION ABOUT COMBIS A. PRODUCT INFORMATION Cleveland Range, LLC assigns two product identification numbers to each Combi: a model nu

Page 46

e When the condensate box is heated to 140 degrees F at the B3probe, 220 VAC is sent from terminal 5 of connector X12 to the condenser valve (Y1) unt

Page 47

CLEVELAND RANGE, LLC1333 East 179th St., Cleveland, Ohio 44110-2574VOLTAGE: WATTAGE: CURRENT: DATESHEET OF REVDRAWN BYDRAWING NO.THIS DESIGN DE

Page 48

BK 2/0BK 2/0BK 2/0-K0GND-X10L1 L2 L3/3.E8126-K113524635E3BK 10-E112.54KW31.5A(@230 VAC)10.111.112.1-X10GND10.211.212.2-K2135246E4-E212.54KW31.5A(@230

Page 49

-K41135246E2 BK 8 -E41 15.75KW39.6A(@230 VAC)10.411.412.4-X10GND35246GND135246GND135246GND-X12112345621 22C2C2C2HOT AIR(TOP OUTER)/5.A1/5.A1/5.

Page 50

2112345621 22/5.C2/5.C2FAN SLOW13 14/5.C2/6.D5-A10:X11:6/2.E6-K3:A2RD 18 22 21-K55.1E5 22 21-K56E6D512345621 22/5.C3/5.C3FAN FAST13 14/5.C3C7123456

Page 51 - CLEVELAND RANGE, LLC

13-Q57.2 14C6-Q57.1 14RD 18C2 13RD 18-X13:4/E51.6-2.5A(1.6A)42W / RD42U / WHTW/GYTW/GY-M1GND1V / BU1W / BN1U / BK2V / YEFANM 3~-X13.1-X13.221123939C8

Page 52 - WIRING DIAGRAM

CABLE CONNECTION SM ON BM CONTROL 50010JUMPERFBS2-6-X10:20/2.E1L2-X1021-X10:DC8X39: 1OPERATION MODULEBM 5010MODULE(OPTION)-A12PICTO-A11-A10X18:1GEN FI

Page 53

-K02-K1-K264153-K41-K42-K61-K62-K3-E112.54KW31.5A(@230VAC)-E2-E3 -E4115.75KW39.6 (@230VAC) -E42 -E61 -E622W / RD2U / WH-M11V / BU1W / BN1U / BK2

Page 54

CONTROL BOARDSM 5010L1- 2O8/240-INPUTMOTOR OVER TEMPDEHUMIDICATION/VALVECONDENSOR/VALVEGEN FILL/VALVEMOTOR OVER TEMPMOTOR / RIGHTMOTOR / LEFTMOTOR / F

Page 55

CLEVELAND RANGE OES 20.20 SEQUENCE OF OPERATIONS When using these instructions refer to the OES 20.20 wiring schematic. 1 When incoming power (220

Page 56

INSTALLATION INSTRUCTIONS A. GENERAL This equipment should be installed only by qualified, professional plumbers, pipe fitters, and electricians.

Page 57 - LADDER DIAGRAM

◊ The normally closed auxiliary contacts of K55.1, K55.2 and K56 open preventing the K57 contactor from energizing. • If the combi fan is in the red

Page 58

e When the condensate box is heated to 140 degrees F at the B3 probe, 220 VAC is sent from terminal 5 of connector X12 to the condenser valve (Y1) un

Page 59 - CLEVELAND RANGE OES 20.20

• For the next 2 minutes 220 VAC is sent from terminal 3 on connector X11 through the normally closed auxiliary contacts of contactor K50 to the K5 c

Page 60

K57 to the coils of contactor K56 and contactors K55.1 for the upper motor and K55.2 for the lower motor ◊ The K56 contactor closes sending 220 VAC t

Page 61

◊ The Contactors K42 and K62 close and 220 VAC is sent to the inner elements (E42 and E62) ◊ If the reduced power option is chosen then Contactors

Page 62

◊ The K57 contactor closes (a) 220 VAC is sent through the Q57.1 thermal overload to the motor and the upper motor turns at a reduced speed. (b) 220

Page 63

f When the timer counts to 0 or the core temp probe (B10) reaches the set amount the cycle ends and the steam generator reverts to the standby temper

Page 64

-B10-B7.1-B6-B5-B3-A13-A11-A10LABELC5013001C5001041C5016006C5016007CORE TEMP. PROBE (KTM CTC)OVEN HI-TEMP THERMOSTATOVEN PROBEBYPASS PROBE6.A43.D86.A4

Page 65

BK 2/0BK 2/0BK 2/0-K0GND-X10L1 L2 L3/3.E812635BU 18/6.F1-X10.21/4.C1-G1:N/4.E1-K5:A2/3.E1-K41:A210.311.312.3-X10/3.A1/3.A1/3.A1FBS 2-I6FBS 2-16FBS 2-1

Page 66

-K41135246E2 BK 8 -E41 15.75KW39.6A(@230 VAC)10.411.412.4-X10GND35246GND135246GND135246GND-X12112345621 22C2C2C2HOT AIR(TOP OUTER)/5.A1/5.A1/5.

Page 67

B. INSTALLATION OF THE COMBI – General Instructions General Instructions: 1. Select the Combi’s operating location. 2. Complete the water, dra

Page 68

2112345621 22/5.C2/5.C2FAN SLOW13 14/5.C2/6.D5-A10:X11:6/2.E6-K3:A2RD 18 22 21-K55.1E5 22 21-K56E6D512345621 22/5.C3/5.C3FAN FAST13 14/5.C3C7123456

Page 69

13-Q57.2 14C6-Q57.1 14RD 18C2 13RD 18-X13:4/E51.6-2.5A(1.6A)42W / RD42U / WHTW/GYTW/GY-M1GND1V / BU1W / BN1U / BK2V / YEFANM 3~-X13.1-X13.221123939C8

Page 70

CABLE CONNECTION SM ON BM CONTROL 50010JUMPERFBS2-6-X10:20/2.E1L2-X1021-X10:DC8X39: 1OPERATION MODULEBM 5010MODULE(OPTION)-A12PICTO-A11-A10X18:1WATER

Page 71

-K0264153-K41-K42-K61-K62 -E4115.75KW39.6 (@230VAC) -E42 -E61 -E622W / RD2U / WH-M11V / BU1W / BN1U / BK2V / YEFAN22 1422 141212FAN FAST-K55.142

Page 72

CONTROL BOARDSM 5010L1- 2O8/240-INPUTMOTOR OVER TEMPDEHUMIDICATION/VALVECONDENSOR/VALVEMOTOR OVER TEMPMOTOR / RIGHTMOTOR / LEFTMOTOR / FASTMOTOR / SLO

Page 73

C. SPECIAL INSTRUCTIONS FOR CASTER EQUIPPED COMBI STANDS AND COMBIS 1. Read all instructions before beginning installation. 2. Level the floor

Page 74

1333 East 179th St., Cleveland, Ohio, U.S.A. 44110Ph: 1-216-481-4900 Fx: 1-216-481-3782 Web Site: www.clevelandrange.comCleveland Range, LLCS