Service & Parts ManualConvotherm Combination Oven-Steamer MODELS: Gas 20.20OGB-20.20OGS-20.2007061333 East 179th St., Cleveland, Ohio, U.S.A. 4411
NOTES:Cleveland Range reserves right of design improvement or modification, as warranted.Many regional, state and local codes exist and it is the resp
1333 East 179th St., Cleveland, Ohio, U.S.A. 44110Ph: 1-216-481-4900 Fx: 1-216-481-3782 Web Site: www.clevelandrange.comCleveland Range, LLCS
NOTES:Cleveland Range reserves right of design improvement or modification, as warranted.Many regional, state and local codes exist and it is the resp
Figure 4-1a Control Panel CONTROL PANEL BASIC OPERATION A. QUICK START GUIDE ALWAYS PRE-HEAT THE OVEN CHAMBER! 1. Switch on with key (1). 2. Se
Figure 4-1b Control Panel B. CONTROL PANEL DETAIL VIEW Note: Item numbers correspond to numbers on the control panels in Figure 4-1b 1. ON/OFF When
Function Indicators • Light up when function or activity is engaged: 10. Reduced Power 11. Burner or Electric Heating ON 12. Reduced Fan Speed 13. Coo
CAUTION Clean the oven chamber at least once per day or more frequently as needed Failure to clean the Combi properly and regularly can cause equipmen
CAUTION Do NOT use U-Shaped racks that are bent or otherwise damaged in any way. Pans and accessories placed in damaged racks can tip and spill, causi
Drain Cover and Drain e. Clean the Bypass Measuring Aperture. (Opening in the oven chamber on the left-hand side, slightly below the door latch. See
B. Semi-Automatic Cleaning of the Oven Chamber NOTE: Do NOT press the Start/Stop key while using the Semi-automatic Cleaning process. This stops the
Table of ContentsInstallation For the Installer . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1Warranty .
a. The third step is Steam mode at 86°F for 1 minute. No action is needed. b. The fourth step is Steam at 212°F for 10 minutes, followed by a Signal
CAUTION Always make sure the cleaning agent containers are correctly connected to the Combi CONVOClean => RED CONVOCare => BLUE or WHITE C. CON
3 “Strong Soiling” 2 hours. 4 ‘Strong Soiling – Shining+” 2 hours and 45 minutes. 8. Press the Smart Key. 9. “Food inside oven?” appears in t
CAUTION Use ONLY the DISSOLVE® Descaler method using Part No. 106174 to descale the Combi. Read, understand, and follow both the descaling procedure i
WARNING This procedure is slightly different depending on the model being descaled. This entire procedure should be read and fully understand as it a
• While adding liquid to the steam generator through the descaler inlets, pour slowly to avoid overflow. • Wipe up any spills at once to avoid etching
C3216313 B0706CLEVELAND RANGE, LLC1333 East 179th St., Cleveland, Ohio 44110-2574THIS DESIGN DESCRIBES A PROPRIETARY ITEM AND IS THE PROPERTY OF CLEVE
C3216313 B0706IITTEEMM QQTTYY PPAARRTT NN00.. DDEESSCCRRIIPPTTIIOONN1 1 C2114828 ASSEMBLY/WELDMENT, TOP, INTERMEDIATE, 12.20/20.20 2 1 C2115487 ASS
C3216313 B0706CLEVELAND RANGE, LLC1333 East 179th St., Cleveland, Ohio 44110-2574THIS DESIGN DESCRIBES A PROPRIETARY ITEM AND IS THE PROPERTY OF CLEVE
C3216313 B0706IITTEEMM QQTTYY PPAARRTT NN00.. DDEESSCCRRIIPPTTIIOONN1 1 C2114828 ASSEMBLY/WELDMENT, TOP, INTERMEDIATE, 12.20/20.202 1 C2115487 ASSE
NOTICEPost instructions to be followed if the user smells gas. Display the instructions in a prominent location. All users of this equipment must unde
300504 A0706COMPONENT PANEL ASSEMBLY, GASOGB 20.20 MODELSCLEVELAND RANGE, LLC1333 East 179th St., Cleveland, Ohio 44110-2574THIS DESIGN DESCRIBES A PR
300504 A0706COMPONENT PANEL ASSEMBLY, GASOGB 20.20 MODELS IITTEEMM QQTTYY PPAARRTT NN00.. DDEESSCCRRIIPPTTIIOONN1 1 C5115405 PLATE, ELECTRICAL M
IITTEEMM QQTTYY PPAARRTT NN00.. DDEESSCCRRIIPPTTIIOONN1 1 C2114297 WELDMENT, CONTROL PANEL2 1 C5019101 CONTROLLER, 5010 OPERATING MODULE3 1
IITTEEMM QQTTYY PPAARRTT NN00.. DDEESSCCRRIIPPTTIIOONN1 4 100413 FOOT ASS'Y, ADJUSTABLE (FOR 1.250 SQ. TUBING), ANCHORABLE TIEDOWN2 1 C211
IITTEEMM QQTTYY PPAARRTT NN00.. DDEESSCCRRIIPPTTIIOONN1 1 C6015215 ELBOW, HOSE CONNECTION, 3/8" WITH SEAL2 2 111647 CLAMP, OETIKER, S/S,
IITTEEMM QQTTYY PPAARRTT NN00.. DDEESSCCRRIIPPTTIIOONN1 1 300453 VALVE ASSEMBLY, 3WAY 240VAC1 1 300363 VALVE ASSEMBLY, 3WAY 120 VAC2 5 11149
C2016143 A0706IITTEEMM QQTTYY PPAARRTT NN00.. DDEESSCCRRIIPPTTIIOONN1 1 300456 VALVE ASSY. 2 WAY 120VAC2 2 111498 HOSE, SILICONE, 3/8" I
IITTEEMM QQTTYY PPAARRTT NN00.. DDEESSCCRRIIPPTTIIOONN1 2 C6015401 BARB, 1/2 R X 3/8 HOSE2 1 C5001085 PRESSURE REGULATING VALVE ODGAS3 1 C6
IITTEEMM QQTTYY PPAARRTT NN00.. DDEESSCCRRIIPPTTIIOONN1 1 C2010050 BURNER INSERT HL, 6.10/6.20, WELDMENT1 C2010052 BURNER INSERT, HL, 10.10/20.1
Cleveland STATEMENT OF POLICIES L I M I T E D W A R R A N T Y CLEVELAND RANGE products are warranted to the original purchaser to be free from defec
Burner insert 20.20 L.P. C2614863-1 Burner Intake Hose C701210023675
Burner insert 20.20 Natural Gas C2614863 Burner Intake Hose C701210023675
IITTEEMM QQTTYY PPAARRTT NN00.. DDEESSCCRRIIPPTTIIOONN1 1 C2616521 BURNER INSERT, HL, PRE-MOUNTED, 6.10/6.201 C2616522 BURNER INSERT, HL, PRE-AS
Complete Assembly LP: C2314903-1 Burner Intake Hose C701210023675
Complete Assembly: C2314903 Burner Intake Hose C701210023675
CLEVELAND RANGE, LLC1333 East 179th St., Cleveland, Ohio 44110-2574THIS DESIGN DESCRIBES A PROPRIETARY ITEM AND IS THE PROPERTY OF CLEVELAND RANGE.THI
IITTEEMM QQTTYY PPAARRTT NN00.. DDEESSCCRRIIPPTTIIOONN1 1 C2514363 ASSEMBLY, OUTER DOOR, 20.202 1 C2514394 ASSEMBLY, INNER DOOR, 20.203 1 C
IITTEEMM QQTTYY PPAARRTT NN00.. DDEESSCCRRIIPPTTIIOONN1 1 C2614806 CARRIAGE PLATE, WELDED, 6.20C2614807 CARRIAGE PLATE, WELDED, 10.10 & 10.
AEDDEBCINSTALLEDORIENTATIONSECTION E-EDETAIL CDETAIL B DETAIL ASECTION D-D4119 20 81472113 214216182011 211017172214 213 961558 14418C2614801 B, C2614
54321C3216313 B0706EXTERIOR SHEETINGALL 20.20 MODELSIITTEEMM QQTTYY PPAARRTT NN00.. DDEESSCCRRIIPPTTIIOONN1 1 C2514356 DOOR, 20.20, COMPLETE2 1 C21
GENERAL INFORMATION ABOUT COMBIS A. PRODUCT INFORMATION Cleveland Range, LLC assigns two product identification numbers to each Combi: a model numb
CLEVELAND RANGE OGB 20.20 SEQUENCE OF OPERATIONS When using these instructions refer to the OGB 6.20 wiring schematic. 1 When 120 VAC is applied t
• If the condensate box is heated to 140 degrees F at the B3probe, 120 VAC is sent from terminal 5 of connector X12 to the condenser valve (Y1) until
(b) 24 VAC is sent from terminal 2 of connector X2 on the Steam Burner Control Module (N21) to the hot surface igniter (R20). (c) The gas valve is ene
• A request for heat is sent from terminal 3 of connector X21 on the Gas Board (A20) to terminal 10 on connector X1 on the Steam Burner Control Modul
◊ Every 120 seconds the rotation of the motor reverses. ◊ NOTE: If the temperature is less than 212 degrees F than fan will be pulsed on for 2 seco
• 120 VAC is sent from terminal 6 of connector X12 on the Control Board (A10) to the Dehumidification Valve (Y2) to pull the humidity out of the cabi
• When the heat circuit is energized the heat symbol will be energized • The cooking mode symbol will be energized. • The time display will invert
CLEVELAND RANGE, LLC1333 East 179th St., Cleveland, Ohio 44110-2574VOLTAGE: WATTAGE: CURRENT: DATESHEET OF REVDRAWN BYDRAWING NO.THIS DESIGN DE
C-M2TW/GYTW/GYV2/WHU2/RDW2/YEM 3~SHGND-X13.4-X13.3BK 18BK 18BK 18-A10:X15:9-A10:X15:10-A10:X15:11V1/BUFANW1/BNU1/BKRPM-BM1.1BKRDBN912379217388-X13.521
BU 18-A1312BK 18WH 1834RD 18D4-A10:X10:12-A10:X10:11D4-A10:X10:10D4-A10:X10:9D4IDENTIFICATION MODULE-B5PROBE BYPASS103BU 18-M3.2-M3.1COOLING FANS-H5.2
INSTALLATION INSTRUCTIONS A. GENERAL This equipment should be installed only by qualified, professional plumbers, pipe fitters, and electricians. 1
-U20:X2:3-U20:X2:4-U20:X2:2/5.C6-U21:X2:3-U21:X2:4-U21:X2:2/6.C6X27:81211109-A203765421HEAT REQUEST310 912 11 36548712345678GAS BOARDGM5010X26:RECIEVE
BU 18RD 18BU 18RD 18GN 18RD 18BU 18 22 21OVER TEMPERATURE THERMOSTAT-B7.1/6.A1N/3.F7N-X1022/3.D5-X10:33/6.A4-X10:35-X1034RD 18(HOT AIR)RD 18BU 1878-K
BU 18RD 18BU 18RD 18GN 18RD 18BU 18/7.A1N/5.A8N-X1024/5.A5-X10:34/7.B2-T3:BK-X1035RD 18GNDGN 18-U21POWER BURNER STEAM GENX1: X2:X3:X1:X2:123 123451234
X3:BURNER (HOT AIR)-T3RD 16RD 16BK 16BU 16WH 16OR 1624 VAC120VAC -X10:24/6.A8BU 18RD 18NGN 18GND-X10104BU 18BU 18BU 18-N22213-A20:X25:12-X10:46/4.B3/4
24 VAC120VAC -T1120VAC -T2RECIEVETRANSMIT12VGND6875MOTOR DRIVE2ARD-Z1L1NNL1FANGNDRxD12VCOMTxDV2/WHW2/YEU2/RD-U10.2SHGNDM 3~CONVECTIONV1/BUU1/BKW1/BN-M
L1- 110/120 VAC-INPUTCONDENSOR/VALVEGEM FILL/VALVESTEAM GEN PUMPPUMP / RINSEDEHUMIDICATION/VALVESTEAM GEN OVER TEMPCOMPARTMENT RINSE V.PUMP / CLEAN
CLEVELAND RANGE OGS 20.20 SEQUENCE OF OPERATIONS When using these instructions refer to the OGS 20.20 wiring schematic. 1 When 120 VAC is applied
a The front display will include a lighted bar under the steam symbol • When the heat circuit is energized the heat symbol will be energized • The
5 With the combi in the Hot Air mode with time on the timer, the door closed and the start switch is depressed a The front display will include a li
. INSTALLATION OF THE COMBI – General Instructions General Instructions: 1. Select the Combi’s operating location. 2. Complete the water, drain, a
◊ In the full mode (3 drops in the display) the Y2 valve will be energized continuously. f When the timer counts to 0 or the core temp probe (B10) r
• If the bypass probe (B5) drops below the set level the steam circuit will start again. e When the condensate box is heated to 140 degrees F at the
◊ The gas valve is energized allowing gas and air into the burner chamber to be ignited by the hot surface igniter. ◊ The Hot Air Burner Control Mod
CLEVELAND RANGE, LLC1333 East 179th St., Cleveland, Ohio 44110-2574VOLTAGE: WATTAGE: CURRENT: DATESHEET OF REVDRAWN BYDRAWING NO.THIS DESIGN DE
C-M2TW/GYTW/GYV2/WHU2/RDW2/YEM 3~SHGND-X13.4-X13.3BK 18BK 18BK 18-A10:X15:9-A10:X15:10-A10:X15:11V1/BUFANW1/BNU1/BKRPM-BM1.1BKRDBN912379217388-X13.521
BU 18-A1312BK 18WH 1834RD 18D5-A10:X10:12-A10:X10:11D4-A10:X10:10D4-A10:X10:9D4IDENTIFICATION MODULE-B5PROBE BYPASS103BU 18-M3.2-M3.1COOLING FANS-H5.2
-U20:X2:3-U20:X2:4-U20:X2:2/5.C6X27:81211109-A203765421HEAT REQUEST310 912 11 36548712345678GAS BOARDGM5010X26:RECIEVETRANSMIT12VGND12VDC IN0VDC INRxD
BU 18RD 18BU 18RD 18GN 18RD 18BU 18 22 21OVER TEMPERATURE THERMOSTAT-B7.1/3.F7N-X1022/3.D5-X10:33-X1034RD 18(HOT AIR)RD 18BU 1878-K06543B4/7.B4GNDGN
X3:BURNER (HOT AIR)-T3RD 16RD 16BK 16BU 16WH 16OR 1624 VAC120VAC -X10:24/5.A8BU 18RD 18NGN 18GND-X10104BU 18BU 18BU 18-N22213-A20:X25:12-X10:46/4.B3/4
24 VAC120VAC -T1RECIEVETRANSMIT12VGND6875MOTOR DRIVE2ARD-Z1L1NNL1FANGNDRxD12VCOMTxDV2/WHW2/YEU2/RD-U10.2SHGNDM 3~CONVECTIONV1/BUU1/BKW1/BN-M2-A20:X250
C. SPECIAL INSTRUCTIONS FOR CASTER EQUIPPED COMBI STANDS AND COMBIS 1. Read all instructions before beginning installation. 2. Level the floor if
FLAMECHECKNEUTRALHI- LIMITRESET AIR HEAT/GOPHASE ( L1 )RESET AIR HEATGND12 10 911 687X1:2154 3HOT SURFACE -N20CONTROL MODULE HOT AIR213X2:GASVALV
L1- 110/120 VAC-INPUTCONDENSOR/VALVEGEM FILL/VALVESTEAM GEN PUMPPUMP / RINSEDEHUMIDICATION/VALVESTEAM GEN OVER TEMPCOMPARTMENT RINSE V.PUMP / CLEAN
1333 East 179th St., Cleveland, Ohio, U.S.A. 44110Ph: 1-216-481-4900 Fx: 1-216-481-3782 Web Site: www.clevelandrange.comCleveland Range, LLCS